Silicone fire sleeve uses a woven fiberglass substrate with a silicone outer coating to provide an external barrier around suitable hoses, cables and pipework near radiant heat or occasional hot splash. It is a protective covering, not a fluid-carrying hose. Choose its inside diameter to allow installation without compressing the hose or preventing necessary movement.
Silicone fire sleeve uses a woven fiberglass substrate with a silicone outer coating to provide an external barrier around suitable hoses, cables and pipework near radiant heat or occasional hot splash. It is a protective covering, not a fluid-carrying hose. Choose its inside diameter to allow installation without compressing the hose or preventing necessary movement.
Provide the hose dimensions, route, service conditions and quantity for a matched quotation.
| Inside diameter (mm) | Wall (mm) | Tolerance (mm) | Roll length (m) |
| 6 | 1.5 | ±0.15 | 50 |
| 8 | 1.5 | ±0.15 | 50 |
| 10 | 2 | ±0.20 | 25 |
| 11 | 2 | ±0.20 | 25 |
| 13 | 2 | ±0.20 | 25 |
| 15 | 2 | ±0.20 | 25 |
| 19 | 2 | ±0.20 | 25 |
| 22 | 2 | ±0.20 | 25 |
| 25 | 2 | ±0.30 | 25 |
| 29 | 2 | ±0.30 | 25 |
| 32 | 2 | ±0.30 | 25 |
| 35 | 3 | ±0.30 | 25 |
| 38 | 3 | ±0.30 | 25 |
| 40 | 3 | ±0.30 | 25 |
| 41 | 3 | ±0.30 | 25 |
| 45 | 3 | ±0.30 | 25 |
| 48 | 3 | ±0.30 | 25 |
| 51 | 3 | ±0.35 | 25 |
| 55 | 3.5 | ±0.35 | 25 |
| 57 | 3.5 | ±0.35 | 25 |
| 60 | 3.5 | ±0.35 | 20 |
| 64 | 3.5 | ±0.35 | 20 |
| 65 | 3.5 | ±0.35 | 20 |
| 70 | 3.5 | ±0.40 | 20 |
| 76 | 4 | ±0.40 | 20 |
| 80 | 4 | ±0.40 | 20 |
| 83 | 4 | ±0.40 | 20 |
| 85 | 4 | ±0.40 | 20 |
| 89 | 4 | ±0.50 | 20 |
| 90 | 4 | ±0.50 | 20 |
| 95 | 4 | ±0.50 | 20 |
| 102 | 5 | ±0.50 | 10 |
| 110 | 5 | ±0.50 | 10 |
| 114 | 5 | ±0.50 | 10 |
| 120 | 5 | ±0.50 | 10 |
| 127 | 5 | ±0.50 | 10 |
| 150 | 6 | ±0.50 | 10 |
Metric dimensions are transcribed from the catalogue. Ambiguous inch/code entries (including 55, 80 and 110 mm rows) are not used as conversions. Packing quantities and weights require confirmation with the quotation.
Describe continuous ambient temperature, radiant heat, direct contact and any splash event separately. The source gives 260–300°C outside and 500–600°C inside without a defined test method or exposure duration; these figures are not adopted as guaranteed service ratings. Request a documented rating for the actual construction before selection.
Check clearance over ferrules, sleeve end treatment and routing around hot surfaces. Confirm whether installation requires disconnecting the line. Replace contaminated or damaged covering according to the system maintenance plan. No fireproof, vehicle-approval or independent certification claim is made on this page.
Tell us the hose outside diameter, fittings to pass, route, heat and abrasion exposure, required length and quantity.



Check the route and the outside diameter before selecting external protection. The hose products below are related enquiry options; listing them here is not a guarantee that every sleeve size is compatible.