SAE 100 R16 reference hydraulic hose uses an oil-resistant nitrile tube and a synthetic-rubber cover in a compact construction. The source structure section specifies two steel-wire braids. Compare both reinforcement and finished outside diameters with the size-specific pressure and bend-radius schedule before selecting the fitting system and routing.
SAE 100 R16 reference hydraulic hose uses an oil-resistant nitrile tube and a synthetic-rubber cover in a compact construction. The source structure section specifies two steel-wire braids. Compare both reinforcement and finished outside diameters with the size-specific pressure and bend-radius schedule before selecting the fitting system and routing.
| Nominal ID (mm) | ID (inch) | Dash | ID min (mm) | ID max (mm) | Reinforcement OD min (mm) | Reinforcement OD max (mm) | OD min (mm) | OD max (mm) | WP (MPa) | WP (psi) | BP (MPa) | Bend radius (mm) | Weight (kg/m) |
| 6.3 | 1/4 | 4 | 6.2 | 7 | 10.7 | 11.7 | 12.6 | 13.8 | 35 | 5075 | 140 | 50 | 0.34 |
| 8 | 5/16 | 5 | 7.7 | 8.5 | 12.1 | 13.3 | 14.4 | 15.6 | 29.7 | 4307 | 118.8 | 55 | 0.39 |
| 10 | 3/8 | 6 | 9.3 | 10.3 | 14.5 | 15.5 | 16.4 | 17.6 | 28 | 4060 | 112 | 65 | 0.49 |
| 12.5 | 1/2 | 8 | 12.3 | 13.5 | 17.9 | 18.9 | 19.9 | 21.1 | 24.5 | 3553 | 98 | 90 | 0.59 |
| 16 | 5/8 | 10 | 15.5 | 16.7 | 21.4 | 22.6 | 23.2 | 24.8 | 21 | 3045 | 84 | 100 | 0.71 |
| 19 | 3/4 | 12 | 18.6 | 19.8 | 25.1 | 26.3 | 27.2 | 28.8 | 21 | 3045 | 84 | 120 | 0.89 |
| 25 | 1 | 16 | 25 | 26.4 | 32.3 | 33.9 | 34.1 | 36.5 | 14 | 2030 | 56 | 150 | 1.37 |
| 31.5 | 1-1/4 | 20 | 31.4 | 33 | 40.3 | 41.9 | 42.8 | 45.2 | 11.3 | 1639 | 45.2 | 210 | 2.27 |
These are catalogue reference values for the stated construction. Confirm the actual reinforcement, hose-and-fitting assembly, pressure cycle and temperature. Burst pressure is not an operating limit, and a standard designation does not establish independent approval.
The detailed source structure lists two braided steel-wire layers, while its opening description refers generally to one or two layers. Confirm the actual supplied construction rather than treating this wording as interchangeable alternatives. Reinforcement and finished diameters in the table serve different assembly checks.
The catalogue describes petroleum- and water-based hydraulic-fluid service with a −40 to +100°C reference range. Confirm the actual fluid, additives, temperature and operating pressure cycle. A compact outside diameter or small bend radius does not establish an impulse rating or suitability for every circuit.
Provide the bore, finished length, mating connections, available bend space, movement and abrasion exposure. Maintain the selected minimum bend radius and avoid twist or crushing. Confirm the complete hose-and-fitting rating and required documentation before ordering.
Send the actual reinforcement, fluid, pressure cycle, temperature, bore, available bend space, assembly length and fittings.



Send the fluid, pressure cycle, temperature, required bore, installed length and fitting specification. Compare each related construction using its own dimensional and pressure schedule.