Micro-pressure testing hose connects a hydraulic test point to a compatible measuring instrument or sampling connection. The small-bore PA tube uses textile reinforcement and a PA or PU outer cover. Choose the complete hose-and-connector assembly for the working pressure, fluid, temperature and routing; the gauge shown is an example of a test arrangement.
Micro-pressure testing hose connects a hydraulic test point to a compatible measuring instrument or sampling connection. The small-bore PA tube uses textile reinforcement and a PA or PU outer cover. Choose the complete hose-and-connector assembly for the working pressure, fluid, temperature and routing; the gauge shown is an example of a test arrangement.
| Reference code | I.D. (mm) | O.D. (mm) | Working pressure (MPa) | Burst pressure (MPa) | Min. bend radius (mm) | Reference length (m) |
| TPH-0240 | 2 | 5 | 40 | 120 | 20 | 100 |
| TPH-0263 | 2 | 5 | 40 | 120 | 20 | 100 |
| TPH-0363 | 3 | 6 | 63 | 160 | 25 | 100 |
| TPH-0450 | 4 | 8 | 50 | 150 | 35 | 100 |
Reference table transcribed from the source, including its TPH-0263 line rated 40 MPa. Do not infer a rating from the item-code suffix. The page introduction mentions 2 and 3 mm bores, while the table also lists 4 mm. Confirm the chosen assembly and connector rating before ordering; a gauge in the photograph does not establish the hose rating.
Specify the test-point thread, mating coupling, hose bore and length, fluid and maximum operating conditions. Hose, fittings and measuring instrument can have different limits; use the lowest verified assembly limit. Confirm whether the line is for an occasional test or permanent monitoring.
The source quotes −40 to +121°C. Confirm the selected tube, cover, fittings and fluid at the actual temperature rather than assuming that every construction shares one continuous rating. The TPH-0263 code does not establish a 63 MPa working rating: its supplied table lists 40 MPa.
Keep the small line clear of sharp edges, crushing, excessive vibration and hot surfaces. Provide the routing and connection drawing for a matched quotation. The catalogue photograph does not establish instrument accuracy, calibration or an assembly approval.
Send the fluid, pressure, temperature, bore, length and both connection details.



Match the test hose, fittings and instrument to the operating conditions. The related hose pages below cover other constructions; their dimensions and pressure limits are not interchangeable.