Reinforced PVC hose reference for confirmed air and water service in mining, construction and quarry equipment. Select the duty and obtain verified application-specific ratings.
The reference construction combines a black PVC tube, polyester-fibre braid and ribbed PVC cover. It is described for selected air and water duties in mining, construction and quarry equipment, with separate standard and heavy-duty configurations.
The source makes fire-retardant, self-extinguishing and standards-compliance claims, but cites inconsistent standard editions and supplies no supporting report. These claims are not transferred as Fronteck certification. Confirm the required flame, electrical and application approvals for the actual supplied assembly.
| ID (inch) | ID (mm) | OD (mm) | WP (psi) | WP (bar) | BP (psi) | BP (bar) | Length (m/roll) | Weight (kg/roll) |
| 3/8 | 10 | 17 | 246.5 | 17 | 986 | 68 | 100 | 20.00 |
| 1/2 | 12 | 20 | 246.5 | 17 | 986 | 68 | 100 | 27.10 |
| 3/4 | 20 | 30.5 | 217.5 | 15 | 870 | 60 | 50 | 28.05 |
| 1 | 25 | 35.5 | 203 | 14 | 812 | 56 | 50 | 33.65 |
| 1-1/4 | 32 | 44 | 145 | 10 | 580 | 40 | 30 | 28.98 |
| 1-1/2 | 40 | 54.5 | 127.6 | 8.8 | 507.5 | 35 | 30 | 43.56 |
| 2 | 50 | 66.5 | 127.6 | 8.8 | 507.5 | 35 | 30 | 61.11 |
Do not use the following pressure values for selection: the heavy-duty source table has major psi/bar mismatches, including 2465 psi paired with 17 bar and 9860 psi paired with 68 bar. Several psi entries differ by approximately tenfold from their bar counterparts. Both columns are retained as unconfirmed source records; request a corrected specification before ordering.
| Reference code | ID (inch) | ID (mm) | Wall (mm) | Source WP psi — unconfirmed | Source WP bar — unconfirmed | Source BP psi — unconfirmed | Source BP bar — unconfirmed | Length (m) | Weight (kg/roll) | Volume (m³/roll) |
| PMHG-10 | 3/8 | 10 | 3.1 | 2465 | 17 | 9860 | 68 | 100 | 16.70 | 0.038 |
| PMHG-12 | 1/2 | 12 | 3.5 | 2465 | 17 | 9860 | 68 | 100 | 22.32 | 0.062 |
| PMHG-20 | 3/4 | 20 | 4.9 | 2175 | 15 | 8700 | 60 | 50 | 25.09 | 0.061 |
| PMHG-25 | 1 | 25 | 4.5 | 2000 | 14 | 8000 | 56 | 50 | 27.30 | 0.093 |
| PMHG-32 | 1-1/4 | 32 | 5.1 | 1450 | 10 | 5800 | 40 | 50 | 38.91 | 0.148 |
| PMHG-40 | 1-1/2 | 40 | 6.2 | 1270 | 8.8 | 5080 | 35 | 50 | 58.91 | 0.210 |
| PMHG-50 | 2 | 50 | 7.2 | 1270 | 8.8 | 5080 | 35 | 50 | 84.70 | 0.361 |
Do not combine the standard-duty pressure with the heavy-duty wall thickness or assume the heavy-duty name establishes a higher pressure. Burst pressure is not an operating rating. The source temperature -10°C to +60°C equals +14°F to +140°F, correcting its lower Fahrenheit error.
Provide air or water service conditions, operating and peak pressures, temperature, length, equipment interface and the relevant application requirements. Obtain the selected construction, corrected pressure schedule, coupling retention and complete assembly specification.
Confirm fire performance, electrical resistance and inspection criteria from actual documentation. Hose colour is only a visual configuration reference. The source’s broad wear, oil and weather-resistance claims do not establish suitability for every mine environment or conveyed fluid.
Specify material, ID and OD, working pressure, temperature, length, connections and quantity.



Send the conveyed material, pressure, temperature, required bore, installed length and fitting specification. Compare each related construction using its own dimensional and pressure schedule.