SAE 100 R5 reference hose uses an oil-resistant NBR tube, a single steel-wire braid and an external fibre-braid cover. Its dimensional schedule differs from other hydraulic hose families, so match the listed bore and outside diameter to the required connections. Discuss the fluid and operating cycle before selecting an assembly.
SAE 100 R5 reference hose uses an oil-resistant NBR tube, a single steel-wire braid and an external fibre-braid cover. Its dimensional schedule differs from other hydraulic hose families, so match the listed bore and outside diameter to the required connections. Discuss the fluid and operating cycle before selecting an assembly.
| Nominal ID (mm) | ID (inch) | Dash | ID min (mm) | ID max (mm) | OD min (mm) | OD max (mm) | WP (MPa) | WP (psi) | BP (MPa) | Bend radius (mm) | Weight (kg/m) |
| 5 | 3/16 | 3 | 4.6 | 5.4 | 12.5 | 13.5 | 21 | 3045 | 84 | 75 | 0.2 |
| 6.3 | 1/4 | 4 | 6.2 | 7 | 14.1 | 15.1 | 21 | 3045 | 84 | 85 | 0.25 |
| 8 | 5/16 | 5 | 7.7 | 8.5 | 16.2 | 17.4 | 15.7 | 2277 | 62.8 | 100 | 0.31 |
| 10 | 3/8 | 6 | 9.3 | 10.3 | 18.4 | 19.6 | 14 | 2030 | 56 | 115 | 0.36 |
| 12.5 | 1/2 | 8 | 12.3 | 13.5 | 22.2 | 23.8 | 12.2 | 1769 | 48.8 | 140 | 0.45 |
| 16 | 5/8 | 10 | 15.5 | 16.7 | 26.2 | 27.8 | 10.5 | 1523 | 42 | 165 | 0.6 |
| 22 | 7/8 | 14 | 22.2 | 23.3 | 30 | 38.8 | 5.6 | 812 | 22.4 | 185 | 0.7 |
| 28.6 | 1-1/8 | 20 | 28.6 | 29.8 | 36.3 | 38.7 | 4.3 | 624 | 17.2 | 360 | 0.85 |
| 34.9 | 1-3/8 | 24 | 34.9 | 36.1 | 42.8 | 45.2 | 3.5 | 508 | 14 | 420 | 1 |
| 46 | 1-3/4 | 32 | 46 | 47.2 | 54.3 | 56.7 | 2.4 | 348 | 9.6 | 480 | 1.4 |
| 60.3 | 2-3/8 | 40 | 60.3 | 61.9 | 70.8 | 73.2 | 2.4 | 348 | 9.6 | 610 | 2.16 |
R5 source dash numbers and bores are retained as printed; do not substitute another hose family using dash alone. The 7/8-inch line has a notably wide 30.0–38.8 mm OD range in the supplied table and requires confirmation. No vehicle brake, steering, fuel or other regulated approval is established by this catalogue reference.
The external fibre braid is a visible construction feature. Confirm abrasion exposure, bend routing, nearby heat and any protective sleeve required. A fibre-covered hose should not be selected as a direct substitute for a rubber-covered design without matching the fitting system and service conditions.
The R5 source uses bore and dash combinations that differ from other hose families. Specify the measured mating dimensions as well as the reference. The 7/8-inch source entry has an unusually wide outside-diameter interval and requires clarification before a fitting is selected.
The source quotes −40 to +100°C and hydraulic-fluid applications. Its wider list of vehicle uses does not establish brake, steering or fuel-system approval. Provide the actual medium, temperature, pressure and required documentation for the selected use.
Provide the exact fluid, pressure, temperature, bore, length and end connections.



Send the required bore and outside diameter, hydraulic fluid, pressure, temperature, length and fitting details. Use each related hose page’s own specification when comparing constructions.