Peristaltic pump hose is compressed by pump rollers or shoes to move the conveyed liquid. The reference construction uses a smooth rubber-compound tube, multiple heavy-duty cord plies and a wrapped synthetic-rubber cover. Match dimensions, compound and reinforcement to the exact pump and fluid.
Peristaltic pump hose is compressed by pump rollers or shoes to move the conveyed liquid. The reference construction uses a smooth rubber-compound tube, multiple heavy-duty cord plies and a wrapped synthetic-rubber cover. Match dimensions, compound and reinforcement to the exact pump and fluid.
Hose dimensions and material directly affect the pump compression setting. Provide the pump model, shoe or roller arrangement, fluid and operating cycle. Do not treat similar bore sizes as interchangeable pump replacements.
| ID (mm) | OD (mm) | Source OD tolerance (mm) | Reinforcement plies | WP (bar) | Length (mm) |
| 10 | 32 | 31/32 | 2 | 8 | 570 |
| 15 | 37 | 36/37 | 2 | 8 | 830 |
| 20 | 37 | 36/37 | 2 | 8 | 830 |
| 25 | 54 | 53/54 | 4 | 16 | 1,090 |
| 32 | 63 | 61/62 | 4 | 16 | 1,300 |
| 38 | 63 | 62/63 | 4 | 16 | 1,300 |
| 40 | 67 | 66/67 | 4 | 16 | 1,500 |
| 45 | 81 | 80/81 | 4 | 16 | 1,850 |
| 50 | 81 | 80/81 | 4 | 16 | 1,850 |
| 60 | 87 | 86/87 | 4 | 16 | 1,850 |
| 65 | 100 | 99/100 | 4 | 16 | 2,335 |
| 80 | 124 | 120/121 | 6 | 16 | 2,910 |
| 100 | 145 | 144/145 | 6 | 16 | 3,410 |
| 125 | 168 | 167/168 | 6 | 16 | 4,000 |
The source graphic repeats an OD heading and places “Tolerance” over a column labelled Ply. The table above identifies the slash-separated dimension column as source OD tolerance and the 2/4/6 column as reinforcement plies, retaining every numerical value.
Dimensional confirmation required: the 32 mm ID row lists OD 63 mm with 61/62 mm tolerance, and the 80 mm ID row lists OD 124 mm with 120/121 mm tolerance. These do not align and must be clarified before ordering. The 15 and 20 mm bores share the same listed OD and length; do not assume a transcription correction without confirmation.
Reference temperature: −40°C to +100°C, subject to the selected rubber compound, fluid and pump duty. The source mentions NR, NBR, CSM, EPDM, silicone and other compounds broadly; it does not assign them to individual size rows. Confirm the actual liner and cover rather than treating all materials as one specification. No burst-pressure schedule is given.
Supply the pump model, rotor arrangement, shoe or roller dimensions and required finished hose length. Confirm inside diameter, outside diameter and tolerance against the pump manufacturer requirements. Resolve the inconsistent OD entries before using the catalogue for a replacement.
Identify the fluid, solids content, temperature, pump speed and pressure. Select the rubber compound for chemical compatibility and repeated compression under those conditions. A list of possible compounds does not establish suitability of every version for the same liquid.
Confirm the fitting design, lubricant requirements and compression setting for the exact pump. Request the applicable pressure and material documents and agree on inspection criteria. General descriptions of low friction or long life do not establish a guaranteed interval or verified performance for a supplied hose.
Specify material, ID and OD, working pressure, temperature, length, connections and quantity.



Send the conveyed material, pressure, temperature, required bore, installed length and fitting specification. Compare each related construction using its own dimensional and pressure schedule.