Bulk material suction and discharge hose uses a pure-gum liner, synthetic-fabric reinforcement and a steel-wire helix for compatible abrasive-material transfer. The reference schedules separate 10 bar and 20 bar versions with different outside diameters. Specify suction, discharge or gravity-flow conditions for the actual material.
Bulk material suction and discharge hose uses a pure-gum liner, synthetic-fabric reinforcement and a steel-wire helix for compatible abrasive-material transfer. The reference schedules separate 10 bar and 20 bar versions with different outside diameters. Specify suction, discharge or gravity-flow conditions for the actual material.
Potential duties include compatible dry cement, sand, gravel and similar bulk materials. Confirm the liner, pressure, vacuum level and electrical continuity requirements for the conveyed medium and installation.
| ID (inch) | ID (mm) | OD (mm) | WP (bar) | WP (psi) | BP (bar) | BP (psi) | Length (m) | Length (ft) |
| 3/4 | 19 | 33 | 10 | 150 | 30 | 450 | 60 | 200 |
| 1 | 25 | 39 | 10 | 150 | 30 | 450 | 60 | 200 |
| 1-1/4 | 32 | 46 | 10 | 150 | 30 | 450 | 60 | 200 |
| 1-1/2 | 38 | 54 | 10 | 150 | 30 | 450 | 60 | 200 |
| 2 | 51 | 67 | 10 | 150 | 30 | 450 | 60 | 200 |
| 2-1/2 | 64 | 81 | 10 | 150 | 30 | 450 | 60 | 200 |
| 3 | 76 | 96 | 10 | 150 | 30 | 450 | 60 | 200 |
| 3-1/2 | 89 | 111 | 10 | 150 | 30 | 450 | 60 | 200 |
| 4 | 102 | 124 | 10 | 150 | 30 | 450 | 60 | 200 |
| 5 | 127 | 151 | 10 | 150 | 30 | 450 | 60 | 200 |
| 6 | 152 | 179 | 10 | 150 | 30 | 450 | 30 | 100 |
| 8 | 203 | 233 | 10 | 150 | 30 | 450 | 30 | 100 |
| ID (inch) | ID (mm) | OD (mm) | WP (bar) | WP (psi) | BP (bar) | BP (psi) | Length (m) | Length (ft) |
| 3/4 | 19 | 33 | 20 | 300 | 60 | 900 | 60 | 200 |
| 1 | 25 | 39 | 20 | 300 | 60 | 900 | 60 | 200 |
| 1-1/4 | 32 | 48 | 20 | 300 | 60 | 900 | 60 | 200 |
| 1-1/2 | 38 | 57 | 20 | 300 | 60 | 900 | 60 | 200 |
| 2 | 51 | 70 | 20 | 300 | 60 | 900 | 60 | 200 |
| 2-1/2 | 64 | 84 | 20 | 300 | 60 | 900 | 60 | 200 |
| 3 | 76 | 99 | 20 | 300 | 60 | 900 | 60 | 200 |
| 3-1/2 | 89 | 113 | 20 | 300 | 60 | 900 | 60 | 200 |
| 4 | 102 | 126 | 20 | 300 | 60 | 900 | 60 | 200 |
| 5 | 127 | 155 | 20 | 300 | 60 | 900 | 60 | 200 |
| 6 | 152 | 182 | 20 | 300 | 60 | 900 | 30 | 100 |
| 8 | 203 | 238 | 20 | 300 | 60 | 900 | 30 | 100 |
Reference temperature: −40°C to +82°C (−40°F to approximately +180°F). Each schedule has twelve size entries. Outside diameters differ between pressure versions; select a complete row. Nominal pressure and metre/foot pairs are retained as published.
The source introduction mentions four helical wires and a static wire, while its structured reinforcement list only states fabric with a steel-wire helix. Confirm the actual wire count and continuity arrangement. No numerical vacuum limit, bend radius or finished-assembly electrical test result is included in these tables. Smooth and corrugated cover versions require confirmation.
Identify the material, particle size, moisture and conveying method. State pressure, vacuum, flow and temperature for the operating cycle. Cement, sand, lime and fertiliser can have different compatibility and wear requirements, so select the liner for the actual medium.
Send the bore, finished length, coupling drawings and installed bend radius. Confirm the selected cover finish and reinforcement for the route. Request the numerical vacuum capability where suction is involved instead of inferring it from the product name.
Specify any required static-dissipation or electrical continuity test for the finished assembly. Agree on wear inspection and replacement criteria for the actual abrasive material. General source claims about conductivity or service life do not establish verified performance for an individual supplied hose.
Specify material, ID and OD, working pressure, temperature, length, connections and quantity.



Send the conveyed material, pressure, temperature, required bore, installed length and fitting specification. Compare each related construction using its own dimensional and pressure schedule.