Layflat fish pump hose is a flexible rubber construction for fish-transfer system enquiries. The reference uses a smooth NR/SBR tube, two high-tensile synthetic-fabric plies and an NR/SBR outer cover. The schedule lists eleven large-bore sizes for 5 bar / 75 psi reference working pressure.
Layflat fish pump hose is a flexible rubber construction for fish-transfer system enquiries. The reference uses a smooth NR/SBR tube, two high-tensile synthetic-fabric plies and an NR/SBR outer cover. The schedule lists eleven large-bore sizes for 5 bar / 75 psi reference working pressure.
Provide the fish-transfer method, pump type, conveyed medium and suction/pressure cycle. Select the hose and end connections for the complete system rather than assuming one configuration suits every species, handling method or pump.
| ID (inch) | ID (mm) | OD (mm) | WP (bar) | WP (psi) | BP (bar) | BP (psi) | Length (m) | Length (ft) |
| 4 | 102 | 112 | 5 | 75 | 15 | 225 | 20 | 65 |
| 5 | 127 | 137 | 5 | 75 | 15 | 225 | 20 | 65 |
| 6 | 152 | 162 | 5 | 75 | 15 | 225 | 20 | 65 |
| 8 | 203 | 213 | 5 | 75 | 15 | 225 | 20 | 65 |
| 10 | 254 | 270 | 5 | 75 | 15 | 225 | 20 | 65 |
| 12 | 304 | 322 | 5 | 75 | 15 | 225 | 20 | 65 |
| 14 | 350 | 366 | 5 | 75 | 15 | 225 | 20 | 65 |
| 16 | 400 | 416 | 5 | 75 | 15 | 225 | 20 | 65 |
| 18 | 450 | 466 | 5 | 75 | 15 | 225 | 20 | 65 |
| 20 | 500 | 516 | 5 | 75 | 15 | 225 | 20 | 65 |
| 24 | 600 | 616 | 5 | 75 | 15 | 225 | 20 | 65 |
Reference temperature: −30°C to +70°C. Working pressure is listed as 5 bar / 75 psi, burst pressure as 15 bar / 225 psi, and length as 20 m / 65 ft for every size. These nominal source pairs are retained.
The source describes 90% vacuum capability and use on both sides of a pump, but does not provide a size- and temperature-specific vacuum test schedule. Confirm the required vacuum definition and limits for the actual assembly. End options such as cuffs or swivel flanges require dimensional and load confirmation. No verified food-contact approval, fish-handling outcome or completed assembly test is established by this reference.
Identify the pump arrangement, required flow, hose length and conveyed water conditions. Provide the expected fish size and handling requirements to the system designer. Choose the bore and end transitions to match the equipment and intended transfer method.
State maximum positive pressure, vacuum level and temperature, including changes during starting and stopping. Confirm the selected layflat construction for those combined conditions. The 90% vacuum description requires an agreed test basis and must not be assumed to apply under every installed bend or operating temperature.
Send cuff or flange drawings, coupling material and support details. Confirm the finished length, minimum installed radius and cleaning procedure. Request any required material-contact documentation and assembly tests; a general fish-pump application does not establish a specific approval or guaranteed handling result.
Specify material, ID and OD, working pressure, temperature, length, connections and quantity.



Send the conveyed material, pressure, temperature, required bore, installed length and fitting specification. Compare each related construction using its own dimensional and pressure schedule.