Porous aeration hose distributes air through its wall for compatible aeration systems. The reference construction is an NR and PE compound, with a dimensional schedule covering different wall thicknesses, bore sizes and weights. Select the hose together with the blower, connectors, installation depth and water conditions.
Porous aeration hose distributes air through its wall for compatible aeration systems. The reference construction is an NR and PE compound, with a dimensional schedule covering different wall thicknesses, bore sizes and weights. Select the hose together with the blower, connectors, installation depth and water conditions.
Provide the required hose length, actual airflow, installation depth, water conditions and connection arrangement. Oxygen-transfer efficiency, continuous temperature limits and pressure rating require defined test or application data.
| Source Type | OD (mm) | Wall thickness (mm) | ID (mm) | Weight (g/m) | Bundle length (m) |
| Ø10-15-C | 10 | 1.5 | 7 | 45 | 200 |
| Ø10-15-BC | 10 | 1.5 | 7 | 45 | 200 |
| Ø10-15-B | 10 | 1.5 | 7 | 45 | 200 |
| Ø14-25-C | 14 | 2.5 | 9 | 85 | 200 |
| Ø14-25-BC | 14 | 2.5 | 9 | 90 | 200 |
| Ø14-25-B | 14 | 2.5 | 9 | 95 | 200 |
| Ø16-30-C | 16 | 3 | 10 | 115 | 200 |
| Ø16-30-BC | 16 | 3 | 10 | 120 | 200 |
| Ø16-30-B | 16 | 3 | 10 | 125 | 200 |
| Ø18-35-C | 18 | 3.5 | 11 | 150 | 200 |
| Ø18-35-BC | 18 | 3.5 | 11 | 155 | 200 |
| Ø18-35-B | 18 | 3.5 | 11 | 160 | 200 |
| Ø20-35-C | 20 | 3.5 | 13 | 160 | 100 |
| Ø20-35-BC | 20 | 3.5 | 13 | 165 | 100 |
| Ø20-35-B | 20 | 3.5 | 13 | 170 | 100 |
| Ø21-40-C | 21 | 4 | 13 | 200 | 100 |
| Ø21-40-BC | 21 | 4 | 13 | 205 | 100 |
| Ø21-40-B | 21 | 4 | 13 | 210 | 100 |
| Ø22-40-C | 22 | 4 | 14 | 205 | 100 |
| Ø22-40-BC | 22 | 4 | 14 | 210 | 100 |
| Ø22-40-B | 22 | 4 | 14 | 215 | 100 |
| Ø25-40-C | 25 | 4 | 17 | 240 | 100 |
| Ø25-40-BC | 25 | 4 | 17 | 245 | 100 |
| Ø25-40-B | 25 | 4 | 17 | 250 | 100 |
| Ø25-50-C | 25 | 5 | 15 | 295 | 100 |
| Ø25-50-BC | 25 | 5 | 15 | 300 | 100 |
| Ø25-50-B | 25 | 5 | 15 | 305 | 100 |
| Ø25-60-C | 25 | 6 | 13 | 310 | 100 |
| Ø25-60-BC | 25 | 6 | 13 | 315 | 100 |
| Ø25-60-B | 25 | 6 | 13 | 320 | 100 |
| Ø25-70-C | 25 | 7 | 11 | 335 | 100 |
| Ø25-70-BC | 25 | 7 | 11 | 340 | 100 |
| Ø25-70-B | 25 | 7 | 11 | 350 | 100 |
| Ø28-40-C | 28 | 4 | 20 | 290 | 100 |
| Ø28-40-BC | 28 | 4 | 20 | 295 | 100 |
| Ø28-40-B | 28 | 4 | 20 | 300 | 100 |
| Ø28-60-C | 28 | 6 | 16 | 350 | 100 |
| Ø28-60-BC | 28 | 6 | 16 | 350 | 100 |
| Ø28-60-B | 28 | 6 | 16 | 360 | 100 |
C, BC and B are the source type suffixes; their material or performance differences are not defined in the supplied schedule. The first group lists 1.5 mm wall thickness despite the source prose saying 2 mm or above; confirm the exact variant. The table provides dimensions, weight and bundle length, not a working-pressure or oxygen-transfer rating.
The product construction and porous hose photograph correspond to the NR and PE compound reference. The source also contains a separate PVC sinking-airline description with incompatible dimensions; that description is not used as the specification for this porous hose.
Check blower capacity, installation depth, hose length, connection losses and water conditions together. The source airflow and power statements do not define a complete test method, so they are not presented as guaranteed oxygen-transfer or energy-performance ratings.
The dimensional table lists thirteen size groups with C, BC and B variants. Confirm the required wall, bore, weight, connection method and bundle length. Request defined pressure, temperature, cleaning and service limits for the actual supplied compound; broad fish-safety, lead-free or all-temperature claims require supporting evidence.
Specify material, ID and OD, working pressure, temperature, length, connections and quantity.



Send the conveyed material, pressure, temperature, required bore, installed length and fitting specification. Compare each related construction using its own dimensional and pressure schedule.