Silicone corrugated hose uses a formed wall and a specified reinforcing construction for suitable flexible air or coolant routes. The source table lists four plies, a 4.5 mm wall and several leg-length choices. Confirm the exact helix-wire construction, bore and minimum bend geometry for the supplied version.
Silicone corrugated hose uses a formed wall and a specified reinforcing construction for suitable flexible air or coolant routes. The source table lists four plies, a 4.5 mm wall and several leg-length choices. Confirm the exact helix-wire construction, bore and minimum bend geometry for the supplied version.
Send dimensions, medium, temperature, pressure or vacuum, length and quantity for a matched quotation.
| Item code | ID (mm; unit inferred from schedule context) | Layers | Wall (mm) | Listed leg options (mm) |
| SCH16 | 16 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH18 | 18 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH20 | 20 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH22 | 22 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH25 | 25 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH28 | 28 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH30 | 30 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH32 | 32 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH35 | 35 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH38 | 38 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH41 | 41 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH43 | 43 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH45 | 45 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH50 | 50 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH54 | 54 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH57 | 57 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH60 | 60 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH63 | 63 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH65 | 65 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH68 | 68 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH70 | 70 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH74 | 74 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH76 | 76 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
| SCH80 | 80 | 4 | 4.5 | 300 / 400 / 500 / 550 / 600 / 650 / 700 / 750 / 800 / 850 / 900 / 950 / 1000 |
Catalogue dimensions require confirmation for the supplied construction. Any ambiguous code, unit or performance statement must be resolved with the quotation; dimensions do not by themselves establish pressure, temperature or approval.
The source mixes coolant and air descriptions with oilfield, hydraulic and impulse wording. Those applications and the generic 0.3–1.2 MPa claim are not adopted as size-specific verified ratings. The ID column omits its unit; metric millimetres are inferred from the schedule context and must be confirmed.
The listed leg lengths are choices, not evidence that every combination is available. Confirm the wire material, bend radius, pressure and vacuum rating. The source −40 to +220°C range requires construction-specific confirmation; direct engine-exhaust service is not established.
Provide a drawing or measured dimensions, fluid or air conditions, temperature, pressure, routing and required documentation.



Compare dimensions, reinforcement, temperature and operating duty before choosing a hose. The related products below are separate enquiry options and do not imply interchangeability or shared approvals.