PVC helix duct hose uses a flexible PVC wall with a rigid PVC spiral for suitable ventilation, dust and light-material conveyance. The reference schedule lists size-dependent positive-pressure and vacuum values with a bend radius measured at the middle of the hose. Match the route and conveyed medium before specifying a size.
PVC helix duct hose uses a flexible PVC wall with a rigid PVC spiral for suitable ventilation, dust and light-material conveyance. The reference schedule lists size-dependent positive-pressure and vacuum values with a bend radius measured at the middle of the hose. Match the route and conveyed medium before specifying a size.
Send the dimensions, conveyed medium, service conditions, required length and quantity to Fronteck.
| ID (mm) | OD (mm) | Overpressure (bar) | Vacuum (bar) | Bend radius (mm) | Length (m) |
| 16 | 21 | 1.2 | 0.26 | 20 | 20 |
| 18.6 | 24.3 | 1.2 | 0.26 | 24 | 20 |
| 20 | 25 | 1.1 | 0.25 | 24 | 20 |
| 25 | 31 | 1 | 0.25 | 30 | 20 |
| 30 | 36 | 0.9 | 0.25 | 35 | 20 |
| 32 | 38 | 0.9 | 0.2 | 35 | 20 |
| 35 | 41 | 0.8 | 0.2 | 35 | 20 |
| 38 | 45 | 0.8 | 0.2 | 45 | 20 |
| 40 | 47 | 0.8 | 0.2 | 50 | 20 |
| 45 | 52 | 0.7 | 0.2 | 55 | 20 |
| 50 | 58 | 0.5 | 0.2 | 60 | 20 |
| 51 | 59 | 0.5 | 0.2 | 60 | 20 |
| 60 | 68 | 0.5 | 0.16 | 70 | 20 |
| 63 | 71 | 0.5 | 0.16 | 70 | 20 |
| 65 | 73 | 0.5 | 0.16 | 70 | 20 |
| 70 | 78 | 0.4 | 0.15 | 90 | 20 |
| 76 | 85 | 0.4 | 0.15 | 100 | 20 |
| 80 | 89 | 0.4 | 0.15 | 110 | 20 |
| 90 | 100 | 0.3 | 0.14 | 125 | 20 |
| 100 | 110 | 0.3 | 0.13 | 140 | 20 |
| 110 | 121 | 0.3 | 0.12 | 150 | 20 |
| 115 | 126 | 0.3 | 0.11 | 155 | 20 |
| 120 | 131 | 0.3 | 0.1 | 160 | 20 |
| 125 | 136 | 0.3 | 0.1 | 170 | 20 |
| 130 | 141 | 0.2 | 0.09 | 170 | 20 |
| 140 | 152 | 0.2 | 0.09 | 175 | 20 |
| 150 | 162 | 0.2 | 0.08 | 180 | 20 |
| 160 | 172 | 0.2 | 0.08 | 190 | 10 |
| 165 | 177 | 0.2 | 0.08 | 190 | 10 |
| 170 | 182 | 0.2 | 0.07 | 190 | 10 |
| 175 | 187 | 0.2 | 0.07 | 190 | 10 |
| 200 | 212 | 0.2 | 0.07 | 215 | 10 |
| 210 | 222 | 0.2 | 0.07 | 225 | 10 |
| 228 | 240 | 0.2 | 0.07 | 240 | 10 |
| 255 | 266 | 0.1 | 0.06 | 272 | 10 |
| 305 | 312 | 0.1 | 0.05 | 325 | 10 |
These catalogue values require confirmation for the actual supplied construction and service. Pressure and vacuum are separate operating conditions, not burst-pressure figures. Any missing or conflicting unit must be resolved before selection.
The catalogue temperature is −10 to +65°C. Confirm the supplied grade and pressure derating at the operating temperature. General references to food processing or chemical resistance are not evidence of food-contact approval or universal compatibility.
Provide bore, pressure differential, airflow or material loading, length and connection type. Keep the hose within its specified bend geometry and check for crushing or wear. The helix and wall must suit the conveyed particles; an accessory or clamp does not increase the hose operating limit.
Provide bore, conveyed air or material, temperature, pressure differential, length, routing and required end connections.



Compare the bore, route, conveyed medium and service conditions before selecting a hose. Related products below are separate enquiry options, not a guarantee of interchangeability.